Product center
The fluorine United States Sri Lanka filter needle felt, FMS products have the characteristics ofhigh-temperature, high-strength, anti-acid corrosion, wear, bending, etc., after different surface chemical treatment and finishing techniques, also having easy cleaning, water repellent and oiltheantistatic function; series of products for different temperature ranges of 150-200 ℃ ,200-250 ℃ ,250-300 ℃.
    Filter with glass fiber filter FMS fluorine Mei Si compared to its wear resistance, fracture resistance and peel strength, can bear high filtration load, the filtration rate of up to 1.5 m / min or higher, running resistance is low. Compared to high temperature synthetic fiber filter media to overcome the the fiber filter elongation, large deformation, low temperature, poor corrosion resistance weaknesses; dimensional stability, strength, better, and cheaper prices in other high-temperature chemical fiber.
    FMS fluorine U.S. Andean filters is the development of new products for China’s national conditions, widely used in iron and steel, nonferrous metal smelting, chemical industry, building materials, electricity and other departments, the use of a large amount of several performance the following table:
Filter name The fluorine U.S. Adams high temperature type The fluorine U.S. Sri Lanka generic type Fluorine U.S. Andean resistant to acid.
Material P84, glass fiber / fiberglass base fabric Kevlar, fiberglass / fiberglass base fabric PPS, glass fiber / fiberglass base fabric
Weight(g/㎡) >800 >800 >800
Thickness(mm) 2.2-3.2 2.5-3.5 2.5-3.5
Air permeability (m³/㎡) 10-20 8-20 10-20
Breaking strength Meridional >2000 >2000 >2000
Zonal >2000 >2000 >2000
Elongation at break Meridional <10% <10% <10%
Zonal <10% <10% <10%
Rupture strength(Mpa/min) 2.9 3.1 3.2
Continuous operating temperature(℃) 260 220 200
Short-time working temperature(℃) 300 360 230
Acid resistance Excellent Good  
Alkali resistance Excellent Excellent  
Wear resistance Excellent
Hydrolytic stability Excellent
15%Antioxidant Good
Post-processing mode PTFE processing, calendering

The air permeability Conversion ways: 1 cubic / square. Min = 16.67L / square sec breathability amount listed in the table in accordance with the calculation method required by the national standard GB/T5453-1997 measured pressure value of 12.7 mm of water.